INDUSTRIAL & EQUIPMENT
ZEH engineers and manufactures the speakers, sounders and microphones that live inside machine HMIs, control cabinets, panel alarms and plant-wide PA. Here the acoustic problem is not hi-fi — it is being heard over 85 dB(A) of compressor noise, surviving washdown and vibration, and staying within the hearing-protection limits your line must respect.
Four families of components, one acoustic supply chain. Every part is built for the duty cycle of a machine that runs three shifts — not for a shelf.
01
Voice-prompt speakers behind membrane panels and HMI bezels that announce cycle states, faults and operator instructions — intelligible at arm’s length over line noise.
02
Panel-mount buzzers and compact sounders from 85 to 105 dB(A) at 1 m, with tone sets your firmware can address — sized for the DIN cut-outs you already use.
03
100 V line transformers, 6–25 W taps and weatherproof horn drivers for announcement and evacuation zones covering whole bays.
04
Corrosion-resistant housings, wide-temperature drivers and enclosures reviewed against ATEX / IECEx zone requirements with your certification body.
ISO 7731 defines when a danger signal is actually heard on a working floor. The table maps its requirements to what we ship with your parts.
| What ISO 7731 asks of a danger signal | How ZEH components meet it |
|---|---|
| A-weighted level ≥ 65 dB(A) everywhere in the reception area | Sounders from 85 dB(A) at 1 m upward; we help you place drivers so the farthest operator position still clears the floor. |
| Signal at least 15 dB above ambient noise at any position | Distance and octave-band data shipped with every sample set, so your installer can verify against measured ambient — not datasheet guesses. |
| Main signal energy between 500 Hz and 1500 Hz | Drivers and horns tuned so the warning band sits inside the window that penetrates hearing protectors and machine masking noise. |
| No startling onset — avoid a jump of more than 30 dB within 0.5 s | Tone envelope advice for your firmware: ramped onset sounders and two-stage signals that alert without the fright reaction. |
Sources: ISO 7731:2003 Clause 6; IEC 60204-1 machine audible alarm practice.
Every sounder family is characterised in our semi-anechoic room at exactly 1 m before a sample ever ships. The same fixture re-tests production lots, so the dB(A) figure in your safety file stays true for the whole series.
Collected from panel builders and machine OEMs we supply — and how the acoustic design side answers them.
A sounder chosen from a catalogue dB figure turns out to be buried by masking noise at the far end of the line.
What ZEH does differently: we model your ambient spectrum first and select the driver band, then verify the farthest position at 1 m-equivalent level.
Operators ignore the panel because fault, warning and cycle-complete tones are indistinguishable beeps.
What ZEH does differently: we build separable tone sets on drivers with honest harmonic response, so your three signal classes stay distinct by ear.
Water ingress through an unsealed grille corrodes the voice coil within months of install.
What ZEH does differently: IP66 / IP69K-sealed constructions with welded or gasketed enclosures, validated by immersed and high-pressure jet testing.
Enter the ambient noise at the operator and the distance — get the required level at the operator and the sounder rating at 1 m, per ISO 7731.
Send ambient levels, mounting cut-outs and the tones your controller can address. ZEH’s industrial desk replies within one business day with driver candidates and the 1 m verification data.