APPLICATIONS / CONFERENCING & EDUCATION

La sala juzga su audio en la primera frase

ZEH builds the drivers and microphones inside conference speakerphones, soundbars, ceiling arrays and classroom voice-reinforcement systems. In a UC meeting, a single sentence of doubled echo or a dropped word ends the meeting’s trust in the device — so every component we ship is measured for the DSP that has to cancel, gate and beamform around it.

Teams / UC

component data formatted for Teams / UC DSP validation workflows

8 m

pickup class — mic arrays and low-noise preamp matching for large-room speakerphones

STI ≥ 0.5

response and directivity data for classroom and voice-alarm intelligibility

Two Rooms, Two Audio Problems

Meeting rooms — full-duplex or the call breaks

Classrooms and lecture halls — every word reaches the last row

Qué exige la certificación UC al transductor

La guía de integración de la pila de audio de Microsoft fija cifras que la mayoría de las hojas de datos de componentes nunca mencionan. Diseñamos y medimos según ellas.

En el lado del micrófono

En el lado del altavoz

Tres asesinos de llamadas que eliminamos por diseño

Vistos en proyectos reales de altavoz de conferencia y aulas que hemos rescatado.

CALL-KILLER 1

El extremo remoto se oye dos veces

Speaker leak into the mic ports exceeds the AEC’s reach, so the far side hears a hollow double of every sentence. ZEH’s fix: port isolation, mic-spacing and gasket design measured as a pair — we hand you the coupling data, not just parts.

CALL-KILLER 2

Un beamforming que no orienta nada

Array channels drift apart after integration — amplitude or phase mismatch quietly disables the beamformer. ZEH’s fix: matched microphones with per-lot channel data, and port-length tooling kept identical across the array.

CALL-KILLER 3

La última fila pide al profesor que repita

One wall speaker fights reverberation, so rear-seat SNR collapses below the 15 dB intelligibility margin. ZEH’s fix: distributed driver layouts with per-unit SPL consistency, verified in batch on the same 1 m fixture.

¿Oirá la última fila cada palabra?

Introduzca el nivel de voz, el tamaño de la sala y el ruido ambiente para comprobar el margen de inteligibilidad en el asiento más alejado.

Cobertura de voz en el asiento más alejado
La práctica en aulas y salas de reuniones mantiene la voz entre 10 y 15 dB por encima del ruido ambiente para que cada palabra resista la reverberación y el ruido de climatización (objetivos EN 60268-16 de STI ≥ 0,5). El nivel cae 6 dB por cada duplicación de la distancia.

Ofrezca a su equipo de DSP un transductor mejor

Envíe la cavidad, la disposición del array y el objetivo de certificación. El equipo de conferencia de ZEH responde en un día hábil con candidatos de transductor y micrófono emparejados, además de datos de acoplamiento.

What you get back